YASKAWA V1000 Quick Start Manual page 159

Ac drive
Hide thumbs Also See for V1000:
Table of Contents

Advertisement

Three-Phase: CIMR-Vo2A
Single-Phase: CIMR-VoBA
Maximum Motor Size Allowed (HP)
<2>
Input Current
Input
<3>
(A)
Rated Output Capacity
(kVA)
Output Current (A)
Output
Overload Tolerance
Carrier Frequency
Max Output Voltage (V)
Max Output Frequency (Hz)
Rated Frequency
Power
Supply
Allowable Voltage Fluctuation
Allowable Frequency Fluctuation
Harmonic Corrective
Actions
<1>
Drives with single-phase power supply input will output three-phase power and cannot run a single-phase motor.
<2>
The motor capacity (HP) refers to a NEC rated 4-pole motor. The rated output current of the drive output amps
should be equal to or greater than the motor rated current.
<3>
Input current rating varies depending on the power supply transformer, input reactor, wiring connections, and
power supply impedance.
<4>
Rated motor capacity is calculated with a rated output voltage of 220 V.
<5>
Carrier frequency is set to 2 kHz (Swing PWM). Current derating is required in order to raise the carrier
frequency.
<6>
Carrier frequency is set to 8 kHz. Current derating is required in order to raise the carrier frequency.
YASKAWA ELECTRIC TOEP C710606 47A YASKAWA AC Drive – V1000 Quick Start Guide
A.2 Single/Three-Phase 200 V Class Drives
Table A.3 Power Ratings Continued
Item
<1>
ND Rating
HD Rating
ND Rating
Three-
Phase
HD Rating
ND Rating
Single-
Phase
HD Rating
ND Rating
<4>
HD Rating
ND Rating
HD Rating
Rated Voltage
DC Link Choke
Specification
0030
0040
-
-
7.5/10.0
10.0
7.5
10.0
37.0
52.0
24.0
37.0
-
-
-
-
11.4
15.2
9.5
12.6
<5>
30.0
40.0
<6>
<6>
25.0
33.0
ND Rating: 120% of rated output current for 1 minute
HD Rating: 150% of rated output current for 1 minute
(Derating may be required for applications that start and
stop frequently)
User-adjustable 2 to 15 kHz
Three-phase power: Three-phase 200 to 240 V
Single-phase power: Three-phase 200 to 240 V
(both proportional to input voltage)
400 Hz (user-adjustable)
Three-phase power: Three-phase 200 to 240 V 50/60 Hz
Single-phase power: 200 to 240 V 50/60 Hz
0056
0069
-
-
20.0
25.0
15.0
20.0
68.0
80.0
52.0
68.0
-
-
-
-
21.3
26.3
17.9
22.9
56.0
69.0
<6>
<6>
47. 0
60.0
-15 to 10%
±5%
Optional
A
159

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents