C.1 European Standards
Three-Phase 200 V / 400 V Class
A – Ground the cable shield
B – Enclosure panel
C – Metal plate
D – Grounding surface
E – Drive
Figure C.2 EMC Filter and Drive Installation for CE Compliance
206
L2
L3
L1
PE
PE
E
L3 L2 L1
J
I
(remove any paint or
sealant)
(Three-Phase 200 V / 400 V Class)
YASKAWA ELECTRIC TOEP C710606 47A YASKAWA AC Drive – V1000 Quick Start Guide
D
R/L1 S/L2 T/L3
U/T1 V/T2 W/T3
R/L1 S/L2 T/L3
U/T1 V/T2 W/T3
H
G
F – Motor cable (braided
shield cable, max. 20 m)
G – Motor
H – Cable clamp
I – Wiring distance as short
as possible
J – EMC noise filter
B
C
E
D
F
A