4.8 No-Load Operation Test Run
3. Press
to give the drive a Run command. RUN will light and
the motor will rotate at 6 Hz.
Ensure the motor is rotating in the correct direction and no faults or
4.
alarms occur.
If there is no error in step 4, press
reference. Increase the frequency in 10 Hz increments verifying
5.
smooth operation results at all speeds. For each frequency, monitor
the drive output current (U1-03) through the LED operator to confirm
the current is well below the motor rated current. Example: 6 Hz →
60 Hz.
6. The drive should operate normally. Press
RUN flashes until the motor comes to a complete stop.
124
Step
to increase the frequency
STOP
to stop the motor.
YASKAWA ELECTRIC TOEP C710606 47A YASKAWA AC Drive – V1000 Quick Start Guide
Display/Result
STOP
Off
On
Motor
Forward
STOP
Flashing
Off

Hide quick links: