Advertisement

Single-Phase 200 V Class
A – Ground the cable shield
B – Enclosure panel
C – Metal plate
D – Grounding surface
(remove any paint or
sealant)
E – Drive
Figure C.3 EMC Filter and Drive Installation for CE Compliance (Single-Phase 200 V
n
EMC Filters
The drive should be installed with the EMC filters listed below in order to comply with the
EN 61800-3, category C1 requirements.
YASKAWA ELECTRIC TOEP C710606 47A YASKAWA AC Drive – V1000 Quick Start Guide
N
L1
PE
PE
E
L1
N
J
I
Class)
C.1 European Standards
C
D
R/L1 S/L2 T/L3
U/T1 V/T2 W/T3
H
F
G
F – Motor cable (braided
shield cable, max. 20 m)
G – Motor
H – Cable clamp
I – Wiring distance as short
as possible
J – EMC noise filter
B
E
D
A
C