YASKAWA V1000 Quick Start Manual page 192

Ac drive
Hide thumbs Also See for V1000:
Table of Contents

Advertisement

B.1 Parameter Table
No.
L3-25
Load Inertia Ratio
L4-01
Speed Agreement Detection Level These parameters configure the multi-function output (H2-
Speed Agreement Detection
L4-02
Width
Speed Agreement Detection Level
L4-03
(+/-)
Speed Agreement Detection Width
L4-04
(+/-)
Frequency Reference Loss
L4-05
Detection Selection
Frequency Reference at Reference
L4-06
Loss
L4-07
Frequency Detection Conditions
Speed Agreement Detection
L4-08
Conditions
L5-01
Number of Auto Restart Attempts
L5-02
Auto Restart Operation Selection
L5-04
Fault Reset Interval Time
L5-05
Fault Reset Operation Selection
L6-01
Torque Detection Selection 1
L6-02
Torque Detection Level 1
L6-03
Torque Detection Time 1
L6-04
Torque Detection Selection 2
L6-05
Torque Detection Level 2
L6-06
Torque Detection Time 2
192
Name
Refer to V1000 Technical Manual for details.
L4: Frequency Detection
Use L4 parameters to configure frequency detection operation.
4, 5) settings "Fref/Fout Agree 1," "Fref/Set Agree 1," "Frequency
Detection 1," and "Frequency detection 2."
Refer to V1000 Technical Manual for details.
0: Stop - Drive will stop
1: Run at L4-06
Refer to V1000 Technical Manual for details.
Refer to V1000 Technical Manual for details.
Refer to V1000 Technical Manual for details.
Note: Available in drive software versions PRG: 1016 and later.
Use L5 parameters to configure Automatic Restart after fault.
Sets the counter for the number of times the drive attempts to restart
when the following faults occur: gF, LF, oC, oV, PF, PUF, rH, rr, oL1,
oL2, oL3, oL4, Uv1.
Refer to V1000 Technical Manual for details.
Refer to V1000 Technical Manual for details.
Refer to V1000 Technical Manual for details.
L6: Overtorque Detection
Use L6 parameters to configure overtorque detection.
0: Disabled
1: oL3 at Speed Agree - Alarm
2: oL3 at RUN - Alarm
3: oL3 at Speed Agree - Fault
5: UL3 at Speed Agree - Alarm
6: UL3 at RUN - Alarm
7: UL3 at Speed Agree - Fault
8: UL3 at RUN - Fault
Sets the overtorque/undertorque detection level.
Sets the length of time an overtorque/undertorque condition must exist
before Torque Detection 1 is triggered.
Refer to V1000 Technical Manual for details.
Refer to V1000 Technical Manual for details.
Refer to V1000 Technical Manual for details.