b1-02
Run Command Selection 1
b1-03
Stopping Method Selection
b1-04
Reverse Operation Selection
b1-07
Local/Remote Run Selection
Run Command Selection while in
b1-08
Programming Mode
b1-14
Phase Order Selection
b1-15
Frequency Reference 2
b1-16
Run Command Source 2
b1-17
Run Command at Power Up
DC Injection Braking Start
b2-01
Frequency
b2-02
DC Injection Braking Current
DC Injection Braking Time/DC
b2-03
Excitation Time at Start
b2-04
DC Injection Braking Time at Stop
b2-08
Magnetic Flux Compensation Value Refer to V1000 Technical Manual for details.
b2-12
Short Circuit Brake Time at Start
b2-13
Short Circuit Brake Time at Stop
Use B3 parameters to configure Speed Search function operation.
b3-01
Speed Search Selection at Start
b3-02
Speed Search Deactivation Current
b3-03
Speed Search Deceleration Time
b3-05
Speed Search Delay Time
YASKAWA ELECTRIC TOEP C710606 47A YASKAWA AC Drive – V1000 Quick Start Guide
0: Operator - RUN and STOP keys on the digital operator.
1: Digital input terminals S1 to S7
2: Memobus communications
3: Option PCB.
0: Ramp to Stop
1: Coast to Stop
2: DC Injection Braking to Stop
3: Coast with Timer (A new run command is ignored if received
before the timer expires)
0: Reverse enabled.
1: Reverse disabled.
Refer to V1000 Technical Manual for details.
0: Run command accepted only in the operation menu.
1: Run command accepted in all menus.
2: Prohibit entering programming mode during Run
Sets phase order for drive output terminals U/T1, V/T2 and W/T3.
0: Standard
1: Switch phase order
Refer to V1000 Technical Manual for details.
Refer to V1000 Technical Manual for details.
Refer to V1000 Technical Manual for details.
b2: DC Injection Braking
Use b2 parameters to configure DC Injection Braking operation
Refer to V1000 Technical Manual for details.
Sets the DC Injection Braking current as a percentage of the drive
rated current.
Sets DC Injection Braking time at start. Disabled when set to 0.00
seconds.
Sets DC Injection Braking time at stop.
Refer to V1000 Technical Manual for details.
Refer to V1000 Technical Manual for details.
b3: Speed Search
Refer to V1000 Technical Manual for details.
Sets the current level at which the speed is assumed to be detected
and Speed Search is ended. Set in percent of the drive rated current.
Sets time constant used to reduce the output frequency during speed
search. Related to a change from max. output frequency to 0.
Refer to V1000 Technical Manual for details.
B.1 Parameter Table
Description
B
169