Configuring Sampling Intervals - OmniSwitch os6900 Network Configuration Manual

Table of Contents

Advertisement

Diagnosing Switch Problems

Configuring Sampling Intervals

The sampling interval is the period of time between polls of the switch's consumable resources to moni-
tor performance vis-a-vis previously specified thresholds. The
configure the sampling interval between health statistics checks.
To configure the sampling interval, enter the health interval command, followed by the number of
seconds.
For example, to specify a sampling interval value of 6 seconds, enter the following command:
-> health interval 6
Valid values for the seconds parameter include 1, 2, 3, 4, 5, 6, 10, 12, 15, 20, or 30.
Note. If the sampling interval is decreased, switch performance be affected.
Viewing Sampling Intervals
The
show health
command can be used to display the current health sampling interval (period of time
between health statistics checks), measured in seconds.
To view the sampling interval, enter the show health configuration command. The currently configured
health sampling interval (measured in seconds) is displayed, as shown below:
-> show health configuration
Rx Threshold
TxRx Threshold
Memory Threshold
CPU Threshold
Sampling Interval (Secs) = 10
OmniSwitch AOS Release 7 Network Configuration Guide
= 80,
= 80,
= 80,
= 80,
June 2013
Monitoring Switch Health
health interval
command can be used to
page 32-45