Configuring 802.1AB
this command. In addition, the Application Priority TLV must be enabled for transmission in the
LLDPDU.
To configure Application Priority TLV parameters, enter the lldp tlv application command, as shown:
-> lldp port 1/1/3 tlv application fcoe priority 3
-> lldp port 1/1/3 tlv application tcp-sctp-port 3192 priority 5
To remove Application Priority TLV parameters, use the no form of the lldp tlv application command, as
shown:
-> lldp chassis tlv application no fcoe
-> lldp chassis tlv application no tcp-sctp-port

Setting the Transmit Interval

To set the transmit time interval for LLDPDUs, enter the
to set the transmit time interval as 40 seconds, enter:
-> lldp transmit interval 40

Setting the Transmit Hold Multiplier Value

To set the transmit hold multiplier value, enter the
example, to set the transmit hold multiplier value to 2, enter:
-> lldp transmit hold-multiplier 2
Note: The Time To Live is a multiple of the transmit interval and transmit hold-multiplier.

Setting the Transmit Delay

To set the minimum time interval between successive LLDPDUs transmitted, enter the
delay
command. For example, to set the transmit delay value to 20 seconds, enter:
-> lldp transmit delay 20

Setting the Reinit Delay

To set the time interval that must elapse before the current status of a port is reinitialized after a status
change, enter the
lldp reinit delay
-> lldp reinit delay 7

Setting the Notification Interval

To set the time interval that must elapse before a notification about the local system Management Informa-
tion Base (MIB) change is generated, enter the
the notification value to 130 seconds, enter:
-> lldp notification interval 130
Note: In a specified interval, generating more than one notification-event is not possible.
page 13-10
lldp transmit interval
lldp transmit hold-multiplier
command. For example, to set the reinit delay to 7 seconds, enter:
lldp notification interval