Quick Steps For Configuring Unp - OmniSwitch os6900 Network Configuration Manual

Table of Contents

Advertisement

Quick Steps for Configuring UNP

Quick Steps for Configuring UNP
Configuring UNP involves defining profiles and setting UNP global and port-based parameters. The
following quick steps provide a brief tutorial for configuring a UNP to authenticate and classify network
devices:
Quick Steps for Configuring Profiles
1
Use the
unp vlan-profile
When traffic received on a port is assigned to the UNP, the port on which the traffic is received is associ-
ated with the specified UNP VLAN. For example, the following command creates the "serverA" profile
and associates the profile with VLAN 500:
-> unp name serverA vlan 500
2
Use the
unp vlan-profile
QoS policy rules to a UNP (see
-> unp name serverA qos-policy-list name serverA_rules
Note. Verify the UNP profile configuration using the
-> show unp
Name
-------------------------------+-----+-------------------------------
serverA
temp_unp
See the OmniSwitch CLI Reference Guide for information about the fields in this display.
Quick Steps for Configuring Global UNP Parameters
The global UNP parameters described in this section are disabled by default. Enabling these parameters is
optional based on the need for the functionality they provide.
1
Use the
unp dynamic-vlan-configuration
UNP VLAN if that VLAN ID does not already exist. The VLAN is created when a device is associated
with the UNP.
-> unp dynamic-vlan-configuration enable
Note. Dynamic UNP VLANs are not saved in the switch configuration file (boot.cfg). When the next
switch reboot occurs, the device ages out, or the UNP is deleted, the dynamic VLAN configuration is
removed.
2
Use the
unp auth-server-down-unp
device is assigned if the RADIUS server is unreachable.
-> unp auth-server-down-unp temp_UNP
page 27-4
command to create a profile and associate that profile with a VLAN ID.
command with the qos-policy-list parameter to optionally assign a list of
"Quick Steps for Configuring QoS Policy Lists" on page
show unp
Vlan
Policy List Name
500
1000
command to enable the switch to automatically create a
command to specify the name of a temporary UNP to which a
OmniSwitch AOS Release 7 Network Configuration Guide
Configuring Universal Network Profiles
command. For example:
serverA_rules
list2
27-7).