Charging Wire; Outline; Removing The Wire Cleaner Of The Primary Charging Assembly; Routing The Charging Wire - Canon iR5000 Service Manual

Hide thumbs Also See for iR5000:
Table of Contents

Advertisement

CHAPTER 4 IMAGE FORMATION SYSTEM

7.8 Charging Wire

7.8.1 Outline

The photosensitive drum is surrounded by three charging wires (for primary charging,
pre-transfer, and transfer/separation).
These charging wires are newly adopted brown wires (0.06 mm in diameter). Do not use a
gold-plated wire, which has been used in the past; otherwise, image faults may occur.
Further, be sure to use a strengthened polishing pad (in a blue holder) as the cleaning pad
for the primary charging assembly and the transfer charging assembly.

7.8.2 Removing the Wire Cleaner of the Primary Charging Assembly

1) Pick the wire cleaner, and disengage the
hook with a flat-blade screwdriver.

7.8.3 Routing the Charging Wire

All charging wires (except the grid wire) are routed more or less in the same way; the fol-
lowing cites the primary charging assembly:
1) Remove the shielding plate (left, right)
of the charging assembly. To prevent
deformation (slack) in the primary
charging assembly, be sure to work
separately for the left shielding plate
and the right shielding plate (i.e., do not
loosen the mounting screws [1] of both
shielding plates at the same time).
2) Remove the wire cleaner.
For other charging assemblies,
remove the two lids.
4-66 P
COPYRIGHT © 2000 CANON INC.
F04-708-01
F04-708-02
2000 2000 2000 2000
CANON iR5000/iR6000 REV.0 JULY 2000
[1]

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ir6000

Table of Contents