7) Insert the drum rotating tool [4] into the
slot [5] in the drum shaft. While keep-
ing the drum in place so that it will not
rotate counterclockwise, insert a screw-
driver into the center opening [6] in the
drum rotating tool to remove the drum
fixing screw.
If the drum is let to rotate coun-
terclockwise, the cleaning blade
will not come into contact with
the drum correctly, leading to
cleaning faults. Be sure to fix
the drum in place first before
removing the drum fixing screw
to avoid the problem.
If the hopper assembly is re-
leased but not removed, be sure
REF.
to open the right upper door and
the right lower door so that
there will be space.
8) Slide out the process unit [7] until it
stops.
COPYRIGHT © 2000 CANON INC.
2000 2000 2000 2000
CANON iR5000/iR6000 REV.0 JULY 2000
CHAPTER 4 IMAGE FORMATION SYSTEM
F04-703-02
[7]
F04-703-03
[5]
Drum shaft
[4]
[6]
4-55 P