Canon iR5000 Service Manual page 411

Hide thumbs Also See for iR5000:
Table of Contents

Advertisement

CHAPTER 6 FIXING SYSTEM
5) Free the harness [3] of the thermistor
from the harness guide.
6) Remove the screw [4], and shift the
thermistor assembly [5] to detach.
When shifting the thermistor
assembly to the rear, take care
not to damage the fixing roller
by the thermistor assembly.
When mounting the thermistor,
be sure that the harness [3] is on
the inner side of the harness
guide [6] of the mounting plate.
Further, take care not to deform
section A when detaching and
attaching the thermistor.
7) Remove the two thermistor retaining
springs [7], and detach the main ther-
mistor [8].
6-30 P
COPYRIGHT © 2000 CANON INC.
[6] [5]
A
[3]
F06-403-10
[7]
F06-403-11
2000 2000 2000 2000
CANON iR5000/iR6000 REV.0 JULY 2000
[4]
[8]