6.2.2 Routing the Scanner Drive Cable

Route the scanner cable to each pulley and hook mirror base in the order indicated:
1) Loosen the screw on the cable fixing plate.
2) Fit the ball of the cable into the hole of the drive pulley, and wind the cable (4 times in-
ward, 5 times outward); then, tape it in place. When winding, be sure that the cable
metal fixing is inside.
3) Hook the cable on each pulley, and temporarily fix one end to the cable fixing plate and
the other end to the hook of the reader frame.
4) Temporarily fix the cable metal fixing to the No. 1 mirror base. (Do not fully secure it.)
5) Mount the reader paper frame.