CHAPTER 3 IMAGE PROCESSING SYSTEM

5. CCD/AP PCB

5.1 Removing the CCD Unit

1) Remove the reader right cover, and de-
tach the copyboard glass.
2) Move the No. 1 mirror base to the left
end.
3) Remove the right upper cover and the
right upper cover base.
4) Remove the reader left cover and the
reader front cover.
5) Remove the eight screws [1], and dis-
connect the connector [2]; then, detach
tje CCD shielding plate [3].
6) Remove the screw [4], and disconnect
the connector [5]; then, free the cable
from the cable clamp [6], and detach the
original sensor unit [7].
7) Remove the four screws [8], and dis-
connect the connector [9]; then, free the
flat cable [10], and free the two fixing
claws [11]. Thereafter, detach the CCD
unit [12].
3-12 R