HP9300(config)# write memory
HP9300(config)# exit
HP9300# reload
NOTE: If you accidentally enter a value that is not within the valid range of values, the CLI will display the valid
range for you.
To increase the number of IP sub-net interfaces you can configure on each port on a Routing Switch from 24 to 64,
then increase the total number of IP interfaces you can configure on the device from 256 to 512, enter the
following commands:
HP9300(config)# system-max subnet-per-interface 64
HP9300(config)# write memory
HP9300(config)# exit
HP9300# reload
Syntax: system-max subnet-per-interface <num>
The <num> parameter specifies the maximum number of sub-net addresses per port and can be from 1 – 64. The
default is 24.
Syntax: system-max subnet-per-system <num>
The <num> parameter specifies the maximum number of sub-net addresses for the entire device and can be from
1 – 512. The default is 256.
HP9300(config)# system-max subnet-per-system 512
HP9300(config)# write memory
HP9300(config)# exit
HP9300# reload
USING THE WEB MANAGEMENT INTERFACE
To modify a table size using the Web management interface:
1.
Log on to the device using a valid user name and password for read-write access. The System configuration
panel is displayed.
2.
Select the Max-Parameter link to display the Configure System Parameter Maximum Value table. This table
lists the settings and valid ranges for all the configurable table sizes on the device.
3.
Click the Modify button next to the row for the table you want to change.
4.
Enter the new value for the table size. The value you enter specifies the maximum number of entries the table
can hold.
5.
Click Apply to save the changes to the device's running-config file.
6.
Select the Save link at the bottom of the dialog. Select Yes when prompted to save the configuration change
to the startup-config file on the device's flash memory.
7.
Click on the plus sign next to Command in the tree view to list the command options.
8.
Select the Reload link and select Yes when the Web management interface asks you whether you really want
to reload the software. Changes to table sizes do not take effect until you reload the software.

Using the Temperature Sensor

The redundant management modules contain a temperature sensor. The temperature sensor generates a Syslog
message and SNMP trap if the temperature exceeds a specified warning level or shutdown level, and can shut the
module down if the temperature exceeds the safe threshold. You can use the CLI or Web management interface
4 - 44