WARNING!  Read and understand the contents of this manual before attempting to service 
WL100 Water Treatment System. Failure to follow the instructions in this manual could 
result in death, serious personal injury, or severe property damage.  Only trained and 
qualified technicians should attempt to install, maintain, or service Waterlogic Equipment. 
 
1. Visually inspect all electrical and water connections for signs of wear or damage.  
 
DANGER!  HIGH VOLTAGE ELECTRICAL HAZARD.  Unplug before inspection and service. 
 
2. Ensure there is adequate (minimum of 2") clearance around the unit and clean the condenser grill 
and compressor fan to provide efficient cooling system operation. 
 
3. Sanitize the Cold Tank per instructions in the pre‐installation procedures. 
 
4. Clean and sanitize external surfaces of the unit.  Use soap and water or chemicals that are 
compatible with ABS plastic and will not damage or degrade the product surfaces.  
 
5.  Remove and clean the Faucet.  Replace as needed. 
 
WARNING!  SANITIZER MAY CONTAIN HAZARDOUS CHEMICALS.  Use of proper personal 
protective equipment such as rubber gloves and eye protection is required.   
 
WL100 Operating, Installation, and Service Manual                     Page 23                                                 Revision: 5‐20‐2016 