WaterLogic WL100 Operating, Installation And Service Manual page 59

Hide thumbs Also See for WL100:
Table of Contents

Advertisement

Dispenses Hot and Cold Water at the Same Time 
 
 
Possible Reason 
Hot or Cold solenoid is stuck 
open. 
 
 
No Cold Water Available 
 
 
Possible Reason 
Closed Water Supply Valve 
Cold Water Solenoid Valve 
malfunction 
Red Heater and Compressor 
Switch on unit is off. 
Loose connection(s) on the 
Display PCB 
Exhausted Filter 
 
 
WL100 Operating, Installation, and Service Manual                     Page 59                                                 Revision: 5‐20‐2016 
Remove Top cover.   
 
Check Hot Solenoid:  Dispense cold water and visually inspect 
tubing for water flow from both tanks. 
 
Check Cold Solenoid:  Disconnect elbow from outlet of cold 
solenoid.  Select hot water and dispense (quickly releasing 
dispensing button to avoid much water coming out of cold 
solenoid. 
 
Replace solenoid as necessary. 
Open the Water Supply Valve 
Inspect the valve components for proper functionality. 
 
 
Turn Red Heater and Compressor Switch on.   
I = ON 
 
 
Turn power off; unplug the unit and visually inspect solenoid 
connections into the Display PCB.   Verify the soldering points 
on connections are secure into the board. 
 
Remove the PCB to inspect the front of the board. 
Replace filters as needed. 
 
Solution 
Solution 