RESETTING THE HOT TANK OVERLOAD OR HIGH LIMIT SAFETY  
 
 
 
 
1. 
Red Compressor/Heater Switch must be in the O=OFF position 
2. 
Unplug the Power Cord from rear of unit. 
3. 
Remove the Lower Front Panel of unit by removing the Phillips head screws underneath 
the Lower Front Panel. 
4. 
Locate the Protective Metal Box on the rear of the hot 
tank.  As you look through the condenser coils on the 
rear of the unit, you will see the hot tank located on the 
right hand side. 
 
 
 
 
 
5. 
From the front of the Water Treatment System, reach 
up behind the hot tank and take hold of the protective 
metal box covering the thermostat and overload on the 
Hot Tank. 
 
There are nuts that secure the Protective Metal Box to 
the Hot Tank, are loose enough to allow you to remove 
the Protective Metal Box. 
 
If the nuts on the metal box are too tight, loosen the 
nuts securing the Hot Tank to the upper base of the 
WL100 Water Treatment System unit and lower the 
Hot Tank so you can remove the Protective Metal Box. 
 
 
WL100 Operating, Installation, and Service Manual                     Page 27                                                 Revision: 5‐20‐2016 