WaterLogic WL100 Operating, Installation And Service Manual page 62

Hide thumbs Also See for WL100:
Table of Contents

Advertisement

Run On – Water continues to dispense out of faucet after releasing the dispense 
button 
 
Reason 
"Run On" or "Carry On" is present in all Waterlogic pressure fed units without outlet 
solenoids. 
 
"Run On" is defined is the amount of water that continues to dispense out of the faucet after 
releasing the dispense button. 
 
Run On exists because the tanks pressurize as water is being dispensed.  Every Waterlogic tank 
has an outlet restrictor to ensure the tanks remain full of water and water is controlled as it is 
released to the faucet.  The inlet solenoid controls flow into the tanks.  The tanks will 
"depressurize" once the dispense button is released the inlet solenoid closes.  A small amount 
of water will "Run On" through the faucet as the tank depressurizes to atmospheric 
conditions. 
 
Typical "Run On" is 2‐3 seconds. 
 
"Run On" can be reduced by installing a pressure limiting device. 
 
The amount of inlet or supply pressure directly impacts the amount of "Run On" as quantified 
below. 
 
WLCP Lab Testing of Rn On 7‐31‐2013 
Pressure 
Pressure 
Static PSI 
Dynamic PSI 
68 
40 
50 
30 
32 
20 
Pressure measured at inlet line to unit.  Static with unit closed.  Dynamic with unit 
dispensing cold water. 
No filters were installed in unit. 
 
 
 
 
 
 
WL100 Operating, Installation, and Service Manual                     Page 62                                                 Revision: 5‐20‐2016 
Time 
Flow Rate 
4 Liters 
I/min 
61 
2.9508197 
72 
2.5 
92 
1.956217 
 
Run On 
Seconds 
2.5 

Hide quick links: