       WARNING!  Read and understand the contents of this manual before attempting to service 
WL250. Failure to follow the instructions in this manual could result in death, serious personal 
injury, or severe property damage.  Only trained and qualified technicians should attempt to 
install, maintain, or service Waterlogic Equipment.* 
 
1. Visually inspect all electrical and water connections for signs of wear or damage.  
 
DANGER!  HIGH VOLTAGE ELECTRICAL HAZARD.  Unplug before inspection and service. 
 
2. Waterlogic recommends changing the UV Lamp every 12 months. 
 
NOTE:  When replacing the UV Lamp the wiring harness must also be 
replaced.   
 
NOTE:  The Glow Starter shown to the right may appear blackened 
which is normal.   
 
      WARNING!  ULTRAVIOLET RADIATION.  Protect your skin and eyes against ultraviolet rays.  
Never look directly at an operating UV light.  Disconnect before removing UV Lamp. 
 
      CAUTION!  UV LAMPS ARE HAZARDOUS.  Lamps are considered Hazardous Waste and must 
be disposed of accordingly.   Refer to Product MSDS sheet for details. 
 
3. Clean the quartz sleeve that surrounds the UV lamp with a non‐abrasive cloth, descaling solution, 
or ultrasonic bath if needed when changing UV lamps. 
 
CAUTION!  UV SYSTEM IS FRAGILE.  Never handle the UV lamp or Quartz Sleeve with bare 
hands.  UV Lamp and quartz sleeve must be free of oils and contaminants to ensure proper 
operation.  Use a soft non‐abrasive cloth to clean. 
 
4. Inspect the Quartz Sleeve O‐ring for wear or damage and replace as necessary. 
 
5. Ensure there is adequate (minimum of 2") clearance around the WL250 Water Treatment System 
and clean the condenser grill and compressor fan to provide efficient cooling system operation. 
 
6. Sanitize the cold tank per instructions in the pre‐installation procedures. 
 
7. Clean and sanitize external surfaces of the WL250 Water Treatment System.  Use soap and water 
or chemicals that are compatible with ABS plastic and will not damage or degrade the product 
surfaces.  
 
8.  Remove and clean the Faucet.  Replace as needed. 
 
WARNING!  SANITIZER MAY CONTAIN HAZARDOUS CHEMICALS.  Use of proper personal 
protective equipment such as rubber gloves and eye protection is required.   
WL250 Operating, Installation, and Service Manual                                                                   Page 21 ‐ Revision:  4‐25‐2016 