Service Requirements - WaterLogic WL500 – Sparkling Operating, Installation And Service Manual

Hide thumbs Also See for WL500 – Sparkling:
Table of Contents

Advertisement

WARNING!
Read and understand the contents of this manual before attempting to
service WL500. Failure to follow the instructions in this manual could result in death,
serious personal injury, or severe property damage. Only trained and qualified
technicians should attempt to install, maintain, or service Waterlogic Equipment.
1. Visually inspect all electrical and water connections for signs of wear or damage.
DANGER!
HIGH VOLTAGE ELECTRICAL HAZARD. Unplug before inspection and service.
2. Waterlogic recommends changing the UV Lamp (CT-2001) every 12 months.
WARNING!
ULTRAVIOLET RADIATION. Protect your skin and eyes against ultraviolet
rays. Never look directly at an operating UV light. Disconnect before removing UV Lamp.
CAUTION!
UV LAMPS ARE HAZARDOUS. Lamps are considered Hazardous Waste and
must be disposed of accordingly. Refer to Product MSDS sheet for details.
3. Clean the quartz sleeve (CT-2002) that surrounds the UV lamp with a non-abrasive cloth,
descaling solution, or ultrasonic bath if needed when changing UV lamps.
CAUTION!
UV SYSTEM IS FRAGILE. Never handle the UV lamp or Quartz Sleeve with
bare hands. UV Lamp and quartz sleeve must be free of oils and contaminants to ensure
proper operation. Use a soft non-abrasive cloth to clean.
Inspect the Quartz Sleeve O-ring (CT-2006) for wear or damage and replace as necessary.
4. Test UV lamp and UV sensor (CDS) is working by removing the sensor from the retaining nut
and covering the end to produce an audible alarm (continuous beep) and "UV Fault" on the
display.
5. The filters should be replaced every 6 months, or 2000 gallons, whichever comes first. Local
water conditions will dictate your exact filter requirements and service intervals. Flush 5
gallons of water through the filters to rinse carbon fines. Do not rinse the filters through the
unit solenoid valve(s) and tanks if at all possible to avoid contamination.
6. Reset Filter Life Timer if enabled. See programming instructions for details.
7. WL500 sparkling tank has a level sensor probe that needs to be maintained and descaled at
every filter change. Level Sensor Probe Part Number is CT-2023-A (10-7250).
WARNING!
HIGH PRESSURE COMPRESSED GAS HAZARD. Isolate CO2 gas supply and
relieve pressure in tank by opening PRV (pressure relief valve) before attempting to remove
the level sensor probe or any other component under pressure.
8. Ensure there is adequate (minimum of 2") clearance around the unit and clean the
condenser grill and compressor fan to provide efficient cooling system operation.
9. Test the drip tray overflow function. Clean and dry off the drip tray and sensors.
10. Sanitize the cold and sparkling tanks per instructions in the pre-installation procedures.
Revision 1.1

SERVICE REQUIREMENTS

Page 27

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents