WaterLogic WL100 Operating, Installation And Service Manual page 15

Hide thumbs Also See for WL100:
Table of Contents

Advertisement

 
Fill the Cold Circuit with Sanitizer 
 
5. Depress the Main Dispensing Button on the Front Control Panel until cold water/sanitizing 
solution comes out the faucet.  NOTE:  Container and drain basin will be required to catch the 
water from the faucet.   
 
WARNING!  Use Personal Protective Equipment.  Gloves and Eye Protection Required.  The first 
8 or 11 Liters (2 or 3 gallons) of water will contain concentrated sanitizer. Use extreme care!  
 
6. Turn off water supply and remove Sanitizing Cartridge from inlet water supply.  Reconnect water 
supply to inlet bulkhead fitting. 
 
Flush Filters 
 
      CAUTION!  FILTER FLUSH REQUIRED. 
 
WL100 Water Treatment Systems are not supplied with filters.  Filters should be configured to 
optimize your system.  Filters need to be configured and specified to do the job given the local 
water conditions, usage, maintenance schedule, and placement restrictions. 
  
In order for our filters to perform as represented and to provide the best quality water possible, it 
is essential that filters be replaced periodically. The frequency of filter changes depends upon your 
water quality and your water usage. For example, if there is a lot of sediment and/or particles in 
your water, then you will have to change your filters more frequently than a location with little to 
no sediment. Be sure to replace your filters whenever you notice a decline in the performance, 
whether it is a drop in flow rate and/or pressure or an unusual taste in the water. 
 
7. Flush thoroughly per filter manufacturers' recommendation with fresh water to drain.  
 
8. Once flushed, install the filters.  Following the flow direction on the filter. 
 
NOTE:
Filters should not be flushed prior to 24 hours before installation to limit Microbial 
  
Growth.   
 
9. Connect WL100 Water Treatment System to power.  
 
       CAUTION!  NEVER TURN ON HEATER BEFORE FILLING HOT TANK. 
 
Red Compressor/Heater Switch must be in the O=OFF position while the Hot 
Tank is empty.  Damage could occur within one minute and the overload (high 
limit) will require manual reset if Heater is turned on with an empty Hot Tank.  
 
 
 
WL100 Operating, Installation, and Service Manual                     Page 15                                                 Revision: 5‐20‐2016 
 

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents