Red Power Switch is lit but the Red LED on the Front is not lit  
 
 
Possible Reason 
Bad Transformer 
Black Power Connector to the 
PCB is not properly connected 
Bad Front PCB (Part Number 
EN‐6130 – WLCP PN 20‐0040) 
Bad Energy Saver PCB (Part 
Number EN‐6131 – WLCP PN 
20‐0075 
Defective Red Heater / 
Compressor Switch 
Compressor Runs But Does Not Chill 
 
 
Possible Reason 
Condenser is dirty 
Reduction of airflow into unit. 
Compressor is running very 
hot. 
 
 
WL100 Operating, Installation, and Service Manual                     Page 52                                                 Revision: 5‐20‐2016 
Replace Transformer 
Properly connect. 
Replace Front PCB 
Replace Energy Saver PCB 
Replace Red Heater / Compressor Switch 
 
Clean the condensing coil of any obstructions or dust. 
Make sure unit is not under minimum ventilation requirements (2 
to 4 inches). 
Low or lost refrigerant.  Refrigerant recharge required. 
 
Solution 
Solution 