Small Amount of Water Periodically Dispenses from Faucet Automatically 
 
 
Possible Reason 
Cold or Hot Water solenoid 
valve malfunction 
Obstruction in solenoid 
housing is preventing proper 
sealing of component. 
 
Dispense Buttons Stick 
 
 
Possible Reason 
Dirt or Foreign material is 
filling the gap around the 
push‐buttons. 
 
 
 
WL100 Operating, Installation, and Service Manual                     Page 61                                                 Revision: 5‐20‐2016 
Inspect valve components for proper function.  Replace as 
necessary. 
Pre‐determine whether water being dispensed is hot / cold. 
Isolate the water supply; push the DISPENSE button to 
release the line pressure, and remove the coil affixed to the 
solenoid stem.   
 
Remove the stem from the solenoid housing and allow water 
from the tank to flush out the contaminant(s). 
Inspect the push buttons and clean surrounding area.   
 
Inspect faucet assembly inside the unit and clean as 
necessary. 
 
Solution 
Solution 