WaterLogic WL100 Operating, Installation And Service Manual page 60

Hide thumbs Also See for WL100:
Table of Contents

Advertisement

Water does not dispense from Unit 
 
 
Possible Reason 
Closed water supply valve 
The unit is not properly 
plugged into electrical outlet 
Red Heater and Compressor 
Switch on unit is in the off 
position 
15 Amp Fuse Blown 
Hot and Cold Solenoid 
connections into the Display 
PCB are loose. 
Exhausted Filter 
 
Cold Water Dispenses from Faucet and Vent Outlet Simultaneously 
 
 
Possible Reason 
Improper tubing attachment 
from the tank to faucet or vice 
versa 
Scale has formed inside cold 
tank outlet tube. 
Expansion chamber in Cold 
Tank is not sealed properly. 
 
 
 
WL100 Operating, Installation, and Service Manual                     Page 60                                                 Revision: 5‐20‐2016 
Open the water supply valve. 
Check electrical outlet connection, or for blown circuit 
breaker. 
 
 
Turn Red Heater and Compressor switch on.   
I = ON 
 
 
Replace the 15 Amp Fuse as needed. 
Turn power off; unplug the unit and visually inspect solenoid 
connections into the Display PCB.   Verify the soldering points 
on connections are secure into the board. 
 
Remove the PCB to inspect the front of the board. 
Replace filters as needed. 
Verify tubing is connected properly from tank outlets to 
correct faucet attachments. 
Remove cold water outlet tube from tank to faucet.   
 
See Hot Tank Descaling Instructions that are included 
further below in this Troubleshooting Section. 
 
Replace Cold Tank. 
 
Solution 
Solution 