Service Requirements - WaterLogic WL400 Operating, Installation And Service Manual

Hide thumbs Also See for WL400:
Table of Contents

Advertisement

WARNING!
Read and understand the contents of this manual before attempting to service
WL400. Failure to follow the instructions in this manual could result in death, serious personal
injury, or severe property damage. Only trained and qualified technicians should attempt to
install, maintain, or service Waterlogic Equipment.
1. Visually inspect all electrical and water connections for signs of wear or damage.
DANGER!
HIGH VOLTAGE ELECTRICAL HAZARD. Unplug before inspection and service.
2. Waterlogic recommends changing the UV Lamp every 6 months.
ULTRAVIOLET RADIATION. Protect your skin and eyes against ultraviolet rays.
WARNING!
Never look directly at an operating UV light. Disconnect before removing UV Lamp.
UV LAMPS ARE HAZARDOUS. Lamps are considered Hazardous Waste and must
CAUTION!
be disposed of accordingly. Refer to Product MSDS sheet for details.
3. Clean the spiral quartz sleeve that surrounds the UV lamp with a non-abrasive cloth, descaling
solution, or ultrasonic bath if needed when changing UV lamps.
UV SYSTEM IS FRAGILE. Never handle the UV lamp or Quartz Sleeve with bare
CAUTION!
hands. UV Lamp and quartz sleeve must be free of oils and contaminants to ensure proper
operation. Use a soft non-abrasive cloth to clean.
4. Sanitize the cold tank per instructions in the pre-installation procedures.
5. Clean and sanitize external surfaces of the unit. Use soap and water or chemicals that are
compatible with ABS plastic and will not damage or degrade the product surfaces.
6. Remove and clean the Faucet. Replace as needed.
SANITIZER MAY CONTAIN HAZARDOUS CHEMICALS. Use of proper personal
WARNING!
protective equipment such as rubber gloves and eye protection is required.
WL400 Operating, Installation, and Service Manual

SERVICE REQUIREMENTS

Page 36 - Revision: 5-29-2015

Advertisement

Table of Contents
loading

Table of Contents