Pre-Installation Procedures - WaterLogic WL100 Operating, Installation And Service Manual

Hide thumbs Also See for WL100:
Table of Contents

Advertisement

 
      DANGER!  ELECTRICAL SHOCK HAZARD.  
Only qualified personnel who have read and understand this entire manual should attempt to 
install, or service this unit, failure to do so could result in death or serious injury.  DO NOT plug 
into an electrical supply until specifically instructed.  
 
 
       WARNING!  ALWAYS SANITIZE BEFORE USE. 
 Sanitize before use to eliminate any potential microbiological contaminates.      
 
Materials Needed:  
 Personal Protective Equipment.  Rubber or Nitrile Safety Gloves and Protective Eyewear  
 Phillips Screwdriver   
 Temperature Gauge 
 Water Pitcher or Container to collect water from the faucet 
 19 Liter (5 gallon) container or drain basin 
 Sanitizer ‐ Household Bleach (5.25% Sodium Hypochlorite) or Citric Acid Based Cleaner 
 ¼" Plastic Tubing, at least 4 feet in length, and assorted ¼" quick connect fittings 
 TDS Meter and Test Strips for measuring chlorine – Optional 
 Sanitizing Cartridge – an empty Waterlogic Filter with cartridge removed 
 
1. Unpack the Waterlogic WL100 Water Treatment System and check exterior for damage.
  
 
Sanitizing 
 
Sanitize using a Household Bleach (5.25% Sodium Hypochlorite solution) or other approved 
cleaner throughout the cold water circuit.  Follow all instructions on the sanitizer and flush with 
fresh water through the faucet until odor and taste is acceptable. 
 
       WARNING!  USE PROPER PERSONAL PROTECTIVE EQUIPMENT 
Always ensure proper ventilation and use proper personal protective equipment such as gloves 
and eye protection when using chemicals.  Refer to Material Safety Data Sheet for specific 
requirements of each chemical product. Take all necessary precautions to prevent sanitizer from 
contacting eyes, clothing, and any other surfaces in could damage (carpets).   
 
2. Put 5 Millimeter (1 Teaspoon) of sanitizer per directions or use Bleach Solution (5 Millimeter = 1 
Teaspoon = 1/6 ounces = ½ cap full) of household bleach (Sodium Hypochlorite 5 ‐ 10% 
Concentration) in the Sanitizing Cartridge.  Always ensure sanitizer is compatible with stainless 
steel and acetyl plastic. 
 
3. Connect sanitizing cartridge to inlet water supply and connect to inlet bulkhead fitting on back of 
unit.  Turn on water supply. 
 
4. Connect power to the WL100 Water Treatment System.  DO NOT TURN ON RED 
HEATER – COMPRESSOR SWITCH AT THIS TIME. Red Compressor/Heater Switch 
must be in the O=OFF position. 
 
 
WL100 Operating, Installation, and Service Manual                     Page 14                                                 Revision: 5‐20‐2016 
PRE‐INSTALLATION PROCEDURES 
 
 