DANGER! ELECTRICAL SHOCK HAZARD.
Only qualified personnel who have read and understand this entire manual should attempt to
install, or service this unit, failure to do so could result in death or serious injury. DO NOT plug
into an electrical supply until specifically instructed.
WARNING! ALWAYS SANITIZE BEFORE USE.
Sanitize before use to eliminate any potential microbiological contaminates.
Materials Needed:
Personal Protective Equipment. Rubber or Nitrile Safety Gloves and Protective Eyewear
Phillips Screwdriver
Temperature Gauge
Water Pitcher or Container to collect water from the faucet
19 Liter (5 gallon) container or drain basin
Sanitizer ‐ Household Bleach (5.25% Sodium Hypochlorite) or Citric Acid Based Cleaner
¼" Plastic Tubing, at least 4 feet in length, and assorted ¼" quick connect fittings
TDS Meter and Test Strips for measuring chlorine – Optional
Sanitizing Cartridge – an empty Waterlogic Filter with cartridge removed
1. Unpack the Waterlogic WL100 Water Treatment System and check exterior for damage.
Sanitizing
Sanitize using a Household Bleach (5.25% Sodium Hypochlorite solution) or other approved
cleaner throughout the cold water circuit. Follow all instructions on the sanitizer and flush with
fresh water through the faucet until odor and taste is acceptable.
WARNING! USE PROPER PERSONAL PROTECTIVE EQUIPMENT
Always ensure proper ventilation and use proper personal protective equipment such as gloves
and eye protection when using chemicals. Refer to Material Safety Data Sheet for specific
requirements of each chemical product. Take all necessary precautions to prevent sanitizer from
contacting eyes, clothing, and any other surfaces in could damage (carpets).
2. Put 5 Millimeter (1 Teaspoon) of sanitizer per directions or use Bleach Solution (5 Millimeter = 1
Teaspoon = 1/6 ounces = ½ cap full) of household bleach (Sodium Hypochlorite 5 ‐ 10%
Concentration) in the Sanitizing Cartridge. Always ensure sanitizer is compatible with stainless
steel and acetyl plastic.
3. Connect sanitizing cartridge to inlet water supply and connect to inlet bulkhead fitting on back of
unit. Turn on water supply.
4. Connect power to the WL100 Water Treatment System. DO NOT TURN ON RED
HEATER – COMPRESSOR SWITCH AT THIS TIME. Red Compressor/Heater Switch
must be in the O=OFF position.
WL100 Operating, Installation, and Service Manual Page 14 Revision: 5‐20‐2016
PRE‐INSTALLATION PROCEDURES