Restricted Flow of Hot Water 
 
 
Possible Reason 
Partially closed water supply valve to 
the unit. 
Hot Tank outlet hole is scaled over. 
Tubing is creased or has a "kink" in it.  Inspect and replace tubing as necessary. 
Faucet nipple screen mesh has 
obstruction(s) 
Exhausted Filter 
Solenoid connection to the Display 
PCB 
Solenoid Valve is Malfunctioning 
 
 
 
WL100 Operating, Installation, and Service Manual                     Page 57                                                 Revision: 5‐20‐2016 
Open water supply valve. 
Descale Tank.   
 
See Hot Tank Descaling Instructions that are included 
further below in this Troubleshooting Section. 
 
See instructional video on the Partner Area of the 
Waterlogic.com website for more information. 
See instructional video on the Partner Area of the 
Waterlogic.com website for more information. 
Unscrew faucet nipple from faucet and remove any 
obstruction(s) from screen mesh. 
Replace the Filter 
Turn power off; unplug the unit and visually inspect 
solenoid connections into the Display PCB.   Verify the 
soldering points on connections are secure into the board. 
 
Remove the PCB to inspect the front of the board. 
Inspect valve components for proper function.  Replace as 
necessary. 
 
Solution 