COLD WATER TROUBLESHOOTING INDEX
1. Cold Water is not Cold (41° +/‐ 5° F)
Cold Water is not Cold (41° +/‐ 5° F)
Possible Reason
No power or refrigeration
elements
Tank has run out of cold water.
Cold tank capacity is 4 liters for
Tower and 2 liters for Counter
Top.
Cold Water Thermostat
Refrigerant has run out
Compressor problem
WL100 Operating, Installation, and Service Manual Page 50 Revision: 5‐20‐2016
Check that the Red Heater and Compressor switch is
on.
Turn Red Heater and Compressor Switch on I = ON
Wait for cold tank to chill water to temperature prior to dispensing
more cold water.
A greater capacity of Waterlogic Water Systems is available.
Check continuity of thermostat with multimeter. Replace
thermostat as required.
Run compressor for at least ten minutes. If condenser is not warm
then refill the refrigerant.
If compressor is not running, repair or replacement is needed.
Solution