WaterLogic WL100 Operating, Installation And Service Manual page 56

Hide thumbs Also See for WL100:
Table of Contents

Advertisement

Steady Drip Out of Faucet 
 
 
Possible Reason 
Debris in Solenoid 
 
 
Hot Water or Steam Coming out of both the Faucet and Vent Hole 
 
 
Possible Reason 
Improper tubing attachment 
from the hot tank to faucet or 
vice versa. 
Hot Water Coming out of Faucet Vent Hole 
 
 
Possible Reason 
Improper tubing attachment 
from the tank to faucet or vice 
versa. 
Hot Tank outlet hole is scaled 
over. 
Expansion chamber is not 
sealed properly. 
 
 
WL100 Operating, Installation, and Service Manual                     Page 56                                                 Revision: 5‐20‐2016 
Inspect Solenoid for debris and clean out as needed. 
Check that the tubing is connected from tank outlets to correct 
faucet attachments.  Connect tubing to outlets as needed. 
 
Verify tubing is connected properly from tank outlets to correct 
faucet attachments. 
Inspect and Descale Tank as needed. 
 
See Hot Tank Descaling Instructions that are included further 
below in this Troubleshooting Section. 
 
See instructional video on the Partner Area of the Waterlogic.com 
website for more information. 
Replace the Hot Tank.   
 
Solution 
Solution 
Solution 