Service Requirements - WaterLogic WL2FW FIREWALL Series Manual

Table of Contents

Advertisement

WARNING!
Read and understand the contents of this manual before attempting to service
WL2FW Water Treatment System. Failure to follow the instructions in this manual could
result in death, serious personal injury, or severe property damage. Only trained and
qualified technicians should attempt to install, maintain, or service Waterlogic Equipment.
1. Visually inspect all electrical and water connections for signs of wear or damage.
DANGER!
HIGH VOLTAGE ELECTRICAL HAZARD. Unplug before inspection and service.
2. Waterlogic recommends changing the UV Lamp every 6 months.
WARNING!
ULTRAVIOLET RADIATION. Protect your skin and eyes against ultraviolet rays.
Never look directly at an operating UV light. Disconnect before removing UV Lamp.
CAUTION!
UV LAMPS ARE HAZARDOUS. Lamps are considered Hazardous Waste and must
be disposed of accordingly. Refer to Product MSDS sheet for details.
3. Clean the Spiral Quartz Sleeve that surrounds the UV Lamp with a non-abrasive cloth, descaling
solution, or ultrasonic bath if needed when changing UV Lamps.
CAUTION!
UV SYSTEM IS FRAGILE. Never handle the UV lamp or Quartz Sleeve with bare
hands. UV Lamp and quartz sleeve must be free of oils and contaminants to ensure proper
operation. Use a soft non-abrasive cloth to clean.
4. Sanitize the Cold Tank per instructions in the pre-delivery procedures.
5. Clean and sanitize external surfaces of the unit. Sanitizing chemicals that are compatible with
ABS plastic and will not damage or degrade the product surfaces.
6. Remove and clean the Faucet. Replace as needed.
WARNING!
SANITIZER MAY CONTAIN HAZARDOUS CHEMICALS. Use of proper personal
protective equipment such as rubber gloves and eye protection is required.
WL2 FW Manual

SERVICE REQUIREMENTS

Page 11 – Revision EU05-07-17