DISABLING ENERGY SAVING SLEEP MODE
All WL100 Water Treatment Systems come from the factory with Energy Saving Sleep Mode 
engaged to meet the Energy Star Certification requirements.  Energy Saving Sleep Mode disables 
the heater circuit if the unit has not been used for a continuous 3 hour or longer period.  
Selecting any button "wakes up" the WL100 Water Treatment System and turns the heater 
circuit back on.  The Hot Tank will typically take less than 10 minutes to heat the water from 
ambient to the 85°C (185°F) set point.   
 
Unplug Power Cord and remove Top Cover to access Energy Saver PCB.  
 
 
Energy Saver PCB – P/N EN‐6131 – WLCP PN 20‐0075 
 
 
 
 
 
WL100 Water Treatment System comes with the 
Energy Saving Sleep Mode "ON"   
 
PCB Jumper JP7 in the "ON" position (Pin 1 and 2)  
 
 
Deactivate the Energy Saving Sleep Mode by moving 
PCB Jumper JP7 to the "OFF" position (Pins 2 and 3).  
 
 
 
WL100 Operating, Installation, and Service Manual                     Page 11                                                 Revision: 5‐20‐2016 
PROGRAMMING INSTRUCTIONS 
 
 
Pin Numbers
 
1  2 
 
 
 
 
 
 
 
 
2  3 
 
 
 
 
 
 
 
3