ADJUSTING COLD SET POINT
The cold set point can be adjusted by accessing the Cold Thermostat
adjustment screw Under the Decal at the rear of the unit.
This will NOT Void the Warranty as the current Decal states on the back of
the unit. The factory set point is 5°C (41°F) that is indicated with the dot
on sheet metal around the adjustment screw and behind the decal.
Turning the adjustment screw clockwise lowers the set point temperature
and the range is approximately ‐6.7°C (20°F) thru the full range of
adjustment (~7:00 to the ~5:00 positions).
You should be able to turn the screw from the factory set point 5°C (41°F)
(~12:00 position) about 45 degrees clockwise (2:30 on a clock) to reduce
the set point temperature by ‐14.4°C (6°F) and achieve the 1.7–2.2°C (35‐
36°F) setting you are looking for.
Trial this by adjusting and then measure the water temperature 10‐15
minutes after the compressor shuts off (coldest point) to verify the set
point temperature.
Each unit will vary slightly. Try not to go much past the "3:00 position" to
avoid freezing the cold tank as shown above.
FUTURE PRODUCTION WILL INCLUDE COLD THERMOSTAT COVER LABEL
Part Number: LP‐0326‐L00‐00 / WLCP PN LP‐0326