Pre-Installation Procedures - WaterLogic infiniti Operating, Installation And Service Manual

Table of Contents

Advertisement

DANGER!
ELECTRICAL SHOCK HAZARD.
Only qualified personnel who have read and understand this entire manual should attempt to
install, or service this unit, failure to do so could result in death or serious injury. DO NOT plug
into an electrical supply until specifically instructed.
WARNING!
ALWAYS SANITIZE BEFORE USE.
Sanitize before use to eliminate any potential microbiological contaminates.
Materials Needed:
• Personal Protective Equipment. Rubber or Nitrile Safety Gloves and Protective Eyewear
• Phillips Screwdriver
• Temperature Gage
• Water Pitcher or Container to collect water from the faucet
• 5-gallon container or drain basin
• Sanitizer - Household Bleach (5.25% Sodium Hypochlorite) or Citric Acid Based Cleaner
• Tapered Tip Squirt Bottle
• ¼" Plastic Tubing, at least 4 feet in length, and assorted ¼" quick connect fittings
• TDS Meter and Test Strips for measuring chlorine - Optional
1. Unpack the Waterlogic infiniti Water Treatment System, and check exterior for damage.
Flush Filters
CAUTION!
FILTER FLUSH REQUIRED.
infiniti Water Treatment Systems, are not supplied with filters. Filters should be configured to
optimize your system. Filters need to be configured and specified to do the job given the local
water conditions, usage, maintenance schedule, and placement restrictions.
In order for our filters to perform as represented and to provide the best quality water possible, it
is essential that filters be replaced periodically. The frequency of filter changes depends upon your
water quality and your water usage. For example, if there is a lot of sediment and/or particles in
your water, then you will have to change your filters more frequently than a location with little to
no sediment. Be sure to replace your filters whenever you notice a decline in the performance,
whether it is a drop in flow rate and/or pressure or an unusual taste in the water.
2. Flush thoroughly per filter manufacturers' recommendation with fresh water to drain.
3. Once flushed, install the filters. Following the flow direction on the filter.
NOTE:
Filters should not be flushed prior to 24 hours before installation to limit Microbial
Growth.
infiniti Operating, Installation, and Service Manual

PRE-INSTALLATION PROCEDURES

Page 12 - Revision: 9-15-2016