DANGER! ELECTRICAL SHOCK HAZARD.
Only qualified personnel who have read and understand this entire manual should attempt to
install, or service this unit, failure to do so could result in death or serious injury.
WARNING! ALWAYS SANITIZE BEFORE USE.
Sanitize before use to eliminate any potential microbiological contaminates.
Red Compressor/Heater Switch must be in the O=OFF position while the Hot
Tank is empty. Damage could occur within one minute and the two Hot Tank
Overload Devices (High Safety Limit) require manual reset if heater is turned
on with an empty Hot Tank.
CAUTION! DRIP TRAY DRAIN.
If you intend to provide a drip tray drain for your customer, be aware that you
will be called multiple times per month to service and unclog the tubing
leading away from the drip tray to drain. Users will clog the drain with paper
clips, erasers, napkins, tea bags, gum, and various other intended items.
Waterlogic recommends you establish a minimum of weekly visits to the
machine for cleaning of the drip tray drain.
Sanitization of Machine
Materials Needed:
Personal Protective Equipment. Rubber or Nitrile Safety Gloves and Protective Eyewear
Phillips Screwdriver
Sanitizer ‐ Household Bleach (5.25% Sodium Hypochlorite) or Citric Acid Based Cleaner
Unused sponges or paper towels
Dish Soap
Clean water
1. Unpack the Waterlogic WL290 Water Treatment System and check exterior for damage.
CAUTION! ALWAYS WASH THE INTERNAL PLASTIC RESERVOIR, LID
AND FLOATS PRIOR TO INSTALLATION.
The internal wetted surfaces of the machine have been handled multiple
times in the process of manufacturing. By following the steps below, you
will ensure the cleanliness and sterility of the drinking water
2. Remove the Top Cover of the WL290 Water Treatment System. The two
screws securing the Top Cover are located in each rear corner.
WL290 Manual
PRE‐INSTALLATION PROCEDURES