Pre-Installation Procedures - WaterLogic WL200 Series Manual

Hide thumbs Also See for WL200 Series:
Table of Contents

Advertisement

DANGER!
ELECTRICAL SHOCK HAZARD.
Only qualified personnel who have read and understand this entire manual should attempt to
install, or service this unit, failure to do so could result in death or serious injury. DO NOT plug
into an electrical supply until specifically instructed.
WARNING!
ALWAYS SANITIZE BEFORE USE.
Sanitize before use to eliminate any potential microbiological contaminates.
CAUTION!
DRIP TRAY DRAIN.
If you intend to provide a drip tray drain for your customer, be aware that you will be called
multiple times per month to service and unclog the tubing leading away from the drip tray to
drain. Users will clog the drain with paper clips, erasers, napkins, tea bags, gum, and various
other intended items. Waterlogic recommends you establish a minimum of weekly visits to
the machine for cleaning of the drip tray drain.
Materials Needed:
· Personal Protective Equipment. Rubber or Nitrile Safety Gloves and Protective Eyewear
· Phillips Screwdriver
· Temperature Gage
· Water Pitcher or Container to collect water from the faucet
· 5 gallon container or drain basin
· Sanitizer - Household Bleach (5.25% Sodium Hypochlorite) or Citric Acid Based Cleaner
· ¼" Plastic Tubing, at least 4 feet in length, and assorted ¼" quick connect fittings
· TDS Meter and Test Strips for measuring chlorine - Optional
1. Unpack the Waterlogic WL200 Water Treatment System and check exterior for damage.
Sanitizing
Sanitize using a Household Bleach (5.25% Sodium Hypochlorite solution) or other approved
cleaner throughout the cold and sparkling water circuits. Follow all instructions on the sanitizer
and flush with fresh water through the faucet until odor and taste is acceptable.
WARNING!
USE PROPER PERSONAL PROTECTIVE EQUIPMENT
Always ensure proper ventilation and use proper personal protective equipment such as gloves
and eye protection when using chemicals. Refer to Material Safety Data Sheet for specific
requirements of each chemical product. Take all necessary precautions to prevent sanitizer
from contacting eyes, clothing, and any other surfaces in could damage (carpets).
2. Put 1 teaspoon of sanitizer per directions or use Bleach Solution (1 teaspoon = 1/6 oz. = 5 ml = ½
cap full) of household bleach (Sodium Hypochlorite 5 - 10% Concentration) in the Sanitizing
Cartridge. Always ensure sanitizer is compatible with stainless steel and acetyl plastic.
WL200 Manual