Pre-Installation Procedures - WaterLogic WL400 Operating, Installation And Service Manual

Hide thumbs Also See for WL400:
Table of Contents

Advertisement

DANGER!
ELECTRICAL SHOCK HAZARD.
Only qualified personnel who have read and understand this entire manual should attempt to
install, or service this unit, failure to do so could result in death or serious injury. DO NOT plug
into an electrical supply until specifically instructed.
WARNING!
ALWAYS SANITIZE BEFORE USE.
Sanitize before use to eliminate any potential microbiological contaminates.
Materials Needed:
• Personal Protective Equipment. Rubber or Nitrile Safety Gloves and Protective Eyewear
• Phillips Screwdriver
• Temperature Gauge
• Water Pitcher or Container to collect water from the faucet
• 5 gallon container or drain basin
• Sanitizer - Household Bleach (5.25% Sodium Hypochlorite) or Citric Acid Based Cleaner
• ¼" Plastic Tubing, at least 4 feet in length, and assorted ¼" quick connect fittings
• TDS Meter and Test Strips for measuring chlorine – Optional
• Sanitizing Cartridge
1. Unpack the Waterlogic WL400 and check exterior for damage.
Sanitizing
Sanitize using a Household Bleach (5.25% Sodium Hypochlorite solution) or other approved
cleaner throughout the cold and sparkling water circuits. Follow all instructions on the sanitizer
and flush with fresh water through the faucet until odor and taste is acceptable.
WARNING!
USE PROPER PERSONAL PROTECTIVE EQUIPMENT
Always ensure proper ventilation and use proper personal protective equipment such as gloves
and eye protection when using chemicals. Refer to Material Safety Data Sheet for specific
requirements of each chemical product. Take all necessary precautions to prevent sanitizer from
contacting eyes, clothing, and any other surfaces in could damage (carpets).
2. Put 1 teaspoon of sanitizer per directions or use Bleach Solution (1 teaspoon = 1/6 oz. = 5 ml = ½
cap full) of household bleach (Sodium Hypochlorite 5 - 10% Concentration) in the Sanitizing
Cartridge. Always ensure sanitizer is compatible with stainless steel and acetyl plastic.
3. Connect sanitizing cartridge to inlet water supply and connect to inlet bulkhead fitting on back of
unit. Turn on water supply.
4. Connect power to WL400. Turn on Red Power Switch. DO NOT TURN ON GREEN
HEATER/COMPRESSOR SWITCH AT THIS TIME.
NEVER TURN ON HEATER BEFORE FILLING HOT TANK.
CAUTION!
WL400 Operating, Installation, and Service Manual

PRE-INSTALLATION PROCEDURES

Page 26 - Revision: 5-29-2015

Advertisement

Table of Contents
loading

Table of Contents