Removal
Remove the DIMM depending on the following procedure.
NOTES:
To remove the failed DIMM, check the error message appearing in
!
POST or ESMPRO to identify the DIMM socket (group) in which the
failed DIMM is installed.
The server operates only when at least two DIMMs are installed.
!
1.
See the section "Preparing for Installation and Removal" described earlier to prepare.
2.
Pull out the server from the rack.
3.
Open the top cover.
Open the levers at both sides of the socket from which you remove the DIMM.
4.
The DIMM is unlock and ready for removal.
5.
Reinstall all parts removed in Step 2.
Power on the server and verify that POST displays no error messages.
If POST displays an error message, take a note on the message and see the POST error
messages listed in6.
Start the SETUP and select [Advanced]
6.
[Enabled] to clear the error information of the removed DIMM. (See Chapter 3 for
details.)
7.
Select "Yes" for [Reset Config Data] on the Advanced menu.
This setting is required to change the hardware configuration data. See Chapter 3 for
details.
Upgrading Your System 7-21
[Memory Configuration]
[Memory Retest]