TeleTek
ADDRESS 90
WALK TEST
WALK TEST
ADDRESS 91
KEYPAD TEST
LED TEST
ADDRESS 92
PGM1, PGM2, PGM3 and SIREN OUTPUTS TEST
OUTPUT TEST
1 PGM1
2 PGM2
3 PGM3
4 SIREN
ADDRESS 93
COMMUNICATOR MONITOR
COMMUNICATOR In this address the functioning of the communicator could be monitored directly.
MONITOR
ADDRESS 94
LOG FILE REVIEW
DISPLAY LOG
CA60Plus

9. CA60Plus TEST MODES

Allows functional zone test. Under this mode the respective activated zone
LED flashes. If an open tamper is present the respective zone LED illuminates
constantly.
Tests the reliability of the LEDs and the keypad buzzer.
PGMs functional test is performed by pressing the key, corresponding to the
respective programmable output. The respective LED illuminates constantly
and the output enters a low level - 0 V. The next pressing of the same key
forces the output to enter a high level - 12 V.
Pressing the ON key starts test transmission from the communicator to the
monitoring station. Pressing the 0 key interrupts the current communication and
erases the non-transmitted events. To exit the address press CLEAR. The LEDs
indication is as follows:
ZONE1: · flashes - waiting for dial tone in process
· illuminates constantly - the process is over
ZONE2: · flashes - phone number dialing in process
· illuminates constantly - the process is over
ZONE3: · flashes - waiting for HANDSHAKE from the monitoring station
in process
· illuminates constantly - the process is over
ZONE4: · flashes - message transmition to the monitoring station in process
· illuminates constantly - the process is over
ZONE5: · flashes - waiting for a confirmation from the monitoring station in
process
· illuminates constantly - the process is over
ZONE6: · illuminates constantly - the communication process is over
After the communication has ended successfully the keypad produces an
audible signal
With the help of the arrow keys the events registered in the memory of the
panel are reviewed. The first visualized event is the last registered.