ADDRESS 15
ZONE 5 - TYPE AND ATTRIBUTES
DEFAULT : PANIC type
ADDRESS 16
ZONE 6 - TYPE AND ATTRIBUTES
DEFAULT : TAMPER type
The zone types options and attributes are listed in Table 1
ENTRY/EXIT
ALARM
PANIC
TAMPER
FIRE
CA60Plus
Programming as in address 11.
Programming as in address 11.
This zone provides time for arming and disarming the area.
When the system is armed, an activated detector in this zone will not cause an
alarm until the programmed EXIT TIME is expired.
When the armed zone is disturbed, the alarm will not be activated until the
programmed ENTRY TIME is expired.
When the ENTRY/EXIT TIME is running, an audible signal from the keypad
buzzer is heard.
This is an instant zone which could be activated only under Security Mode. It
activates the PGMs and the SIREN output having ALARM attributes and the
communicator.
When the zone is activated, the MEMORY LED and the zone LED light. After
disarming the system these LEDs continue lighting until a user code is entered
or the system is armed again.
In disarmed condition of the system the active status of this zone is indicated by
the respective LED flashing while the zone is open.
Silent Panic - only the programmable PANIC type outputs and the
communicator are activated. When the zone is activated, the respective LED
flashes. There is no memory indication. When a valid user code is entered the
MEMORY LED and the zone LED illuminate constantly. The memory is erased
either by reentering a valid user code or when the system is armed again.
Audible Panic - activates the PGMs and the SIREN output having ALARM
and/or PANIC attributes and the communicator. The sirens are instantly activated
regardless the programmed delay time. When the zone is activated, the
MEMORY LED and the zone LED illuminate constantly. The memory is erased
either by reentering a valid user code or when the system is armed again.
The active status of this zone type activates the SIREN output, the TAMPER
programmed outputs and the communicator.
When the area is disarmed and the TAMPER siren output is programmed as
"silent", the TAMPER activation will cause the keypads buzzer to produce an
audible signal.
When the zone is activated, the TAMPER LED and the zone LED illuminate
constantly. The memory is erased only by entering an engineer or a master
code. Constantly open TAMPER is indicated by flashing LED TAMPER.
Allows the connecting of 12 V fire detectors to the system. They should have a
normally closed dry contacts in passive condition and an open circuit in alarm
condition.
When the detector is activated, the SIREN output, the FIRE type proggrammed
outputs and the communicator are activated.
When the zone is activated the MEMORY LED flashes and the zone LED
illuminates constantly regardless the operating mode of the system.
The memory is erased either by reentering a valid user code or when the system
is armed.
Table 1. Zone types and attributes