Reset Parameters Table; Appendix A - Teletek electronics CA60Plus Installation Manual

Security control panel
Hide thumbs Also See for CA60Plus:
Table of Contents

Advertisement

TeleTek

APPENDIX A

PROGRAM MENU
ADDRESS
LOOP TYPE
ZONE 1
ATTRIBUTES ZONE 1
ZONE 2
ATTRIBUTES ZONE 2
ZONE 3
ATTRIBUTES ZONE 3
ZONE 4
ATTRIBUTES ZONE 4
ZONE 5
ATTRIBUTES ZONE 5
ZONE 6
ATTRIBUTES ZONE 6
PGM 1
PGM 2
PGM 3
SIREN OUTPUT
EXIT TIME
ENTRY TIME
BELL TIME
BELL DELAY
SET WITH CODE
USER CODE 1
USER CODE 2
USER CODE 3
USER CODE 4
USER CODE 5
USER CODE 6
MANGER ACCESS
ENGINEER CODE
RESET ENABLE
DEFAULT SETTINGS
PART. RESET
54 to 89 address indication, concerning the communicator parameters, is hexadecimal, the LEDs 3,4,5,6 are
TEL No PC FOR UDL
PC ID FOR UDL
PANEL ID FOR UDL
CALL BACK
No OF RINGS
ANSW. MACHINE
TEL No 1
PANEL ID 1
REPORT 1
х1/х2
TEL No 2
PANEL ID 2
REPORT 2
х1/х2
WAIT DIAL TONE
RESET Parameters
CA60Plus
LED 1
LED 2
10
DUAL - LED1 to LED6 do not light
11 ! Entry/Exit
ALARM
" FOLLOW
DOUBLE
12 ! Entry/Exit
ALARM
" FOLLOW
DOUBLE
13 ! Entry/Exit
ALARM
" FOLLOW
DOUBLE
14 ! Entry/Exit
ALARM
" FOLLOW
DOUBLE
15 ! Entry/Exit
ALARM
" FOLLOW
DOUBLE
16 ! Entry/Exit
ALARM
" FOLLOW
DOUBLE
21 !
ALARM
PANIC
" MEDICAL PS/bypass AC LOSS
22 !
ALARM
PANIC
" MEDICAL PS/bypass AC LOSS
23 !
ALARM
PANIC
" MEDICAL PS/bypass AC LOSS
24
ALARM
PANIC
30
0-9 SEC
10-19 SEC 20-29 SEC 30-39 SEC 40-49 SEC 50 - 59 SEC
31
0-9 SEC
10-19 SEC 20-29 SEC 30-39 SEC 40-49 SEC 50 - 59 SEC
32
1 MIN
2 MIN
33
1 MIN
2 MIN
40
NO - LED1 to LED6 do not light
41
UNSET
FULSET PARTSET1 PARTSET2
42
UNSET
FULSET PARTSET1 PARTSET2
43
UNSET
FULSET PARTSET1 PARTSET2
44
UNSET
FULSET PARTSET1 PARTSET2
45
UNSET
FULSET PARTSET1 PARTSET2
46
UNSET
FULSET PARTSET1 PARTSET2
47
NO - LED1 to LED6 do not light
50
51
NO - LED1 to LED6 do not light
52
Press the keys from 1 to 6 consequently and confirm by ENTER
53
Press the keys from 1 to 6 consequently and confirm by ENTER
used (Lower BIT - LED 6)
54
Max phone number lenght 16 symbols, pause=ON+2, DTMF =ON+1
55
4 digits. Default 1234
56
4 digits. Default 1234
57
NO - LED1 to LED6 do not light
58
1 digit. (0 to 9)
59
NO - LED1 to LED6 do not light
60
Max phone number lenght 16 symbols, pause=ON+2, DTMF =ON+1
61
3 or 4 digits (depending on the report 3х or 4х)
62
The report number included in the applied table is entered
63
x2 - LED1 to LED6 do not light
64
Max phone number lenght 16 symbols, pause=ON+2, DTMF =ON+1
65
3 or 4 digits (depending on the report 3х or 4х)
66
The report number included in the applied table is entered
67
x2 - LED1 to LED6 do not light
68
NO - LED1 to LED6 do not light

RESET Parameters Table

LED 3
LED 4
ALARM - LED1 to LED6 light
PANIC
TAMPER
PART1
PART2
PANIC
TAMPER
PART1
PART2
PANIC
TAMPER
PART1
PART2
PANIC
TAMPER
PART1
PART2
PANIC
TAMPER
PART1
PART2
PANIC
TAMPER
PART1
PART2
TAMPER
FIRE
BAT LOW
TAMPER
FIRE
BAT LOW
TAMPER
FIRE
BAT LOW
TAMPER FIRE/ALW
3 MIN
4 MIN
3 MIN
4 MIN
YES - LED1 to LED6 light
YES - LED1 to LED6 light
DIGIT 1
DIGIT 2
YES - LED1 to LED6 light
YES - LED1 to LED6 light
YES - LED1 to LED6 light
x1 - LED1 to LED6 light
x1 - LED1 to LED6 light
YES - LED1 to LED6 light
29
Installation Manual
LED 5
LED 6
FIRE
MEDICAL
CHIME
FAST
FIRE
MEDICAL
CHIME
FAST
FIRE
MEDICAL
CHIME
FAST
FIRE
MEDICAL
CHIME
FAST
FIRE
MEDICAL
CHIME
FAST
FIRE
MEDICAL
CHIME
FAST
FIRE/RST
ON/OFF
FUSE
Pol+ / -
FIRE/RST
ON/OFF
FUSE
Pol+ / -
FIRE/RST
ON/OFF
FUSE
Pol+ / -
5 MIN
6 MIN
5 MIN
6 MIN
LOG
BYPASS
LOG
BYPASS
LOG
BYPASS
LOG
BYPASS
LOG
BYPASS
LOG
BYPASS
DIGIT 3
DIGIT 4