5. Programmable Outputs PGM1, PGM2 and PGM3

The PGM1, PGM2 and PGM3 security panel outputs have a programmable active level. Thus they
could be used for generating managing signals to exterior units (for example a siren with a blocking input)
or direct managing of low power exterior units (such as relays, LEDs, etc.).
The two ways of using the programmable outputs are described on Fig. 6 and Fig. 8.
Fig. 6 describes a LED and relay management through the programmable outputs PGM. The active
level of these outputs is low.
CA60Plus
Fig. 6 LED and Relay Management by PGM1
The SIREN output of the control panel is designed for siren managing. A managing signal toward a
siren with blocking input could be generated or power supply managed siren provided. The two ways of
using the SIREN output are discribed on Fig. 7 and Fig. 8.
On Fig.7 is described the SR110E siren (produced by TeleTek
been used. When an alarm event occurs the SIREN output switches to a low level and powers up the
siren SR110E.
Fig. 7 Two-wires SIREN Management
CA60Plus
COM
Z2
SIREN
PGM3
PGM2
PGM1
+PGM
-AUX
+AUX
AC
and PGM2

6. Programmable Output SIREN

COM
Z2
SIREN
PGM3
PGM2
PGM1
+PGM
-AUX
+AUX
AC
CA60Plus
1k
) wiring. The SIREN output has
®
-12 V
+12 V
SR110E
7
Instalation Manual
RELAY