Detectors Wiring - Teletek electronics CA60Plus Installation Manual

Security control panel
Hide thumbs Also See for CA60Plus:
Table of Contents

Advertisement

TeleTek
The CA60 Plus control panel operates with dry relay contacts detectors. It is also possible fire detectors
with a relay output to be used.
To balance the zones use the applied 1 kΩ resistors. The balancing resistors should be housed in the
last detector in the chain.
The zones that will not be used should be terminated with a 1 kΩ resistor on the terminals regardless
the chosen zone balancing type.
After the initial powering up of the security panel the zone balancing type should be programmed. By
default the balancing is ALARM type.
On Fig. 9 a, b and c are described the possible variants of wiring the detectors and balancing the zones.
ZONE x
COM
TAMPER
ZONE
COM
а) Connecting Detectors with One Balancing Resistor
ZONE x
COM
b) Connecting Detectors with Two Balancing Resistors
ZONE x
COM
C) Connecting up to Four Detectors with Two Balancing Resistors
Fig. 9 Possibilities for Connecting Detectors
to the Security Panel
CA60Plus

7. Detectors Wiring

NC
NC
RELAY 1
RELAY 2
NC
NC
TAMPER 1
TAMPER 2
NC
NC
RELAY 1
RELAY 2
NC
NC
TAMPER 2
TAMPER 1
NC
NC
RELAY 1
RELAY 2
1k
1k
NC
NC
TAMPER 1
TAMPER 2
9
Installation Manual
NC
RELAY n
1k
NC
TAMPER n
1k
1k
NC
RELAY n
1k
NC
TAMPER n
NC
RELAY n
1k
1k
NC
TAMPER n

Advertisement