CB FALCON MODBUS COMMUNICATION
Table 10. Falcon alert codes
478
Internal error: Safety key bit 0 was incorrect
479
Internal error: Safety key bit 1 was incorrect
480
Internal error: Safety key bit 2 was incorrect
481
Internal error: Safety key bit 3 was incorrect
482
Internal error: Safety key bit 4 was incorrect
483
Internal error: Safety key bit 5 was incorrect
484
Internal error: Safety key bit 6 was incorrect
485
Internal error: Safety key bit 7 was incorrect
486
Internal error: Safety key bit 8 was incorrect
487
Internal error: Safety key bit 9 was incorrect
488
Internal error: Safety key bit 10 was incorrect
489
Internal error: Safety key bit 11 was incorrect
490
Internal error: Safety key bit 12 was incorrect
491
Internal error: Safety key bit 13 was incorrect
492
Internal error: Safety key bit 14 was incorrect
493
Internal error: Safety key bit 15 was incorrect
494
Internal error: Safety relay timeout
495
Internal error: Safety relay commanded off
496
Internal error: Unknown safety error occurred
497
Internal error: Safety timer was corrupt
498
Internal error: Safety timer was expired
499
Internal error: Safety timings
500
Internal error: Safety shutdown
501
RESERVED
502
Mix setpoint was invalid
503
Mix time of day setpoint was invalid
504
Mix outdoor temperature was invalid
505
Mix ODR time of day setpoint was invalid
506
Mix ODR time of day setpoint exceeds normal
setpoint
507
Mix ODR max outdoor temperature was invalid
508
Mix ODR min outdoor temperature was invalid
509
Mix ODR low water temperature was invalid
510
Mix ODR outdoor temperature range was invalid
511
Mix ODR water temperature range was invalid
512
Mix demand switch was invalid
513
Mix ON hysteresis was invalid
514
Mix OFF hysteresis was invalid
515
Mix ODR min water temperature was invalid
516
Mix hysteresis step time was invalid
517
Mix P-gain was invalid
518
Mix I-gain was invalid
519
Mix D-gain was invalid
520
Mix control was suspended due to fault
521
Mix S10 (J10-7) temperature was invalid
522
Mix outlet temperature was invalid
523
Mix inlet temperature was invalid
524
Mix S5 (J8-11) temperature was invalid
Table 10. Falcon alert codes
525
Mix modulation sensor type was invalid
526
Mix ODR min water temperature setpoint was invalid
527
Mix circulator sensor was invalid
528
Mix flow control was invalid
529
Mix temperature was invalid
530
Mix sensor was invalid
531
Mix PID setpoint was invalid
532
STAT may not be a Mix demand source when
Remote Stat is enabled
533-539 RESERVED
540
Delta T inlet/outlet enable was invalid
541
Delta T exchanger/outlet enable was invalid
542
Delta T inlet/exchanger enable was invalid
543
Delta T inlet/outlet degrees was out of range
544
Delta T exchanger/outlet degrees was out of range
545
Delta T inlet/exchanger degrees was out of range
546
Delta T response was invalid
547
Delta T inversion limit response was invalid
548
Delta T rate limit enable was invalid
549
Delta T exchanger/outlet wasn't allowed due to stack
limit setting
550
Delta T inlet/outlet limit was exceeded
551
Delta T exchanger/outlet limit was exceeded
552
Delta T inlet/exchanger limit was exceeded
553
Inlet/outlet inversion occurred
554
Exchanger/outlet inversion occurred
555
Inlet/exchanger inversion occurred
556
Delta T exchanger/outlet wasn't allowed due to stack
connector setting
557
Delta T inlet/exchanger wasn't allowed due to stack
limit setting
558
Delta T inlet/exchanger wasn't allowed due to stack
connector setting
559
Delta T delay was not configured for recycle
response
560
Outlet T-rise enable was invalid
561
Heat exchanger T-rise enable was invalid
562
T-rise degrees was out of range
563
T-rise response was invalid
564
Outlet T-rise limit was exceeded
565
Heat exchanger T-rise limit was exceeded
566
Heat exchanger T-rise wasn't allowed due to stack
limit setting
567
Heat exchanger T-rise wasn't allowed due to stack
connector setting
568
Outlet T-rise wasn't allowed due to outlet connector
setting
569
T-rise delay was not configured for recycle response
570
Heat exchanger high limit setpoint was out of range
571
Heat exchanger high limit response was invalid