Cfc Falcon Parameters - CleaverBrooks CFC Operation, Service & Parts Manual

Condensing boiler
Table of Contents

Advertisement

• High Limits
• Stack Limit
• Other Limits
• Anti-condensation Configuration
• Frost Protection Configuration
• Annunciation Configuration
• Burner Control Interlocks
• Burner Control Timings & Rates
• Burner Control Ignition
• Burner Control Flame Failure
• System Configuration
• Fan Configuration
• Lead Lag Configuration
Parameter Group
Parameter Name
System ID & Access
Burner name
System ID & Access
Installation data
System ID & Access
OEM identifica-
tion
System ID & Access
Installer password
System ID & Access
MB1 (Modbus
address)
System ID & Access
MB2 (Modbus
address)
Central Heat Configu-
CH enable
ration
Central Heat Configu-
CH demand
ration
switch
Central Heat Configu-
CH modulation
ration
sensor
Central Heat Configu-
CH setpoint
ration
Central Heat Configu-
CH TOD setpoint
ration
Central Heat Configu-
CH on hysteresis
ration
Central Heat Configu-
CH off hysteresis
ration
Central Heat Configu-
CH P gain
ration
Central Heat Configu-
CH I gain
ration
Central Heat Configu-
CH D gain
ration
Central Heat Configu-
CH hysteresis
ration
step time
Central Heat Configu-
CH setpoint
ration
source
Central Heat Configu-
CH modulation
ration
rate source
Central Heat Configu-
CH has priority
ration
over LL
Central Heat Configu-
CH 4 mA water
ration
temperature
Central Heat Configu-
CH 20 mA water
ration
temperature
Outdoor Reset Config-
CH outdoor reset
uration
enable
Part No. 750-263
Table 4-1 CFC Falcon Parameters
Min.
Max.
Access
Range
Range
Service
Service
Read
Only
Service
Service
Service
user
user
user
user
32
210
user
32
194
Service
2
60
Service
2
60
Service
Service
Service
Service
Service
Service
Service
Service
194
Service
194
Service
Paramet
Default Setting -
Default Setting -
er Units
CFC-500 to -2500
BOILER 1
BOILER 1
SERIAL NUMBER
SERIAL NUMBER
FALCON 833-
FALCON 833-
03639
04086
9220
9220
1
1
1
1
Enabled
Enabled
B:STAT terminal
B:STAT terminal
A:Modulation from
A:Modulation from
Outlet (S3S4) sen-
Outlet (S3S4) sen-
sor
sor
°F
150
150
°F
120
120
°F
5
5
°F
15
15
25
25
25
25
0
0
mmm ss
1m 0s
1m 0s
A:Local setpoint is
A:Local setpoint is
used
used
A:Local modula-
A:Local modula-
tion (PID) is used
tion (PID) is used
No/False/Off
No/False/Off
°F
60
60
°F
180
180
Disabled
Disabled
Section 4 — CFC Commissioning
Installation Setting
CFC-3300
Modbus
Register
(dec)
183
184
185
190
625
625
208
209
210
211
212
213
214
216
217
218
219
578
580
582
583
584
215
4-7

Advertisement

Table of Contents
loading

Table of Contents