CleaverBrooks CFC Operation, Service & Parts Manual page 257

Condensing boiler
Table of Contents

Advertisement

Table 50. Alerts. (Continued)
Code
296
Abnormal Recycle: Interrupted air flow switch
297
Abnormal Recycle: Interrupted air flow switch
298
Abnormal Recycle: Interrupted air flow switch
299
Abnormal Recycle: Interrupted air flow switch
300
Abnormal Recycle: Interrupted air flow switch
301
Abnormal Recycle: Interrupted air flow switch
302
Abnormal Recycle: Ignition failed due to
303
Abnormal Recycle: ILK off during Drive to Purge
304
Abnormal Recycle: ILK off during Measured
305
Abnormal Recycle: ILK off during Drive to
306
Abnormal Recycle: ILK off during Pre-Ignition
307
Abnormal Recycle: ILK off during Pre-Ignition
308
Abnormal Recycle: ILK off during Main Flame
309
Abnormal Recycle: ILK off during Ignition period
310
Run was terminated due to ILK was off
311
Run was terminated due to interrupted air flow
312
Stuck reset switch
313
Run was terminated due to fan failure
314
Abnormal Recycle: Fan failed during Drive to
315
Abnormal Recycle: Fan failed during Measured
316
Abnormal Recycle: Fan failed during Drive to
317
Abnormal Recycle: Fan failed during Pre-Ignition
318
Abnormal Recycle: Fan failed during Pre-Ignition
319
Abnormal Recycle: Fan failed during Ignition
320
Abnormal Recycle: Fan failed during Main Flame
321
Abnormal Recycle: Main Valve off after 10
322
Abnormal Recycle: Pilot Valve off after 10
323
Abnormal Recycle: Safety Relay off after 10
324
Abnormal Recycle: Hardware flame bias
325
Abnormal Recycle: Hardware static flame
326
Abnormal Recycle: Hardware flame current
327
Abnormal Recycle: Hardware flame rod short
328
Abnormal Recycle: Hardware invalid power
329
Abnormal Recycle: Hardware invalid AC line
330
Abnormal Recycle: Hardware SLO flame ripple
331
Abnormal Recycle: Hardware SLO flame sample
332
Abnormal Recycle: Hardware SLO flame bias
333
Abnormal Recycle: Hardware SLO flame bias
334
Abnormal Recycle: Hardware SLO spark stuck
335
Abnormal Recycle: Hardware SLO spark
336
Abnormal Recycle: Hardware SLO static flame
337
Abnormal Recycle: Hardware SLO rod shorted
338
Abnormal Recycle: Hardware SLO AD linearity
Description
Table 50. Alerts. (Continued)
Code
339
Abnormal Recycle: Hardware SLO bias not set
340
Abnormal Recycle: Hardware SLO bias shorted
341
Abnormal Recycle: Hardware SLO electronics
342
Abnormal Recycle: Hardware processor clock
343
Abnormal Recycle: Hardware AC phase
344
Abnormal Recycle: Hardware A2D mismatch
345
Abnormal Recycle: Hardware VSNSR A2D
346
Abnormal Recycle: Hardware 28V A2D
347
Abnormal Recycle: Hardware HFS IAS shorted
348
Abnormal Recycle: Hardware PII INTLK shorted
349
Abnormal Recycle: Hardware HFS LCI shorted
350
Abnormal Recycle: Hardware HFS LFS shorted
351
Abnormal Recycle: Invalid zero crossing
352
Abnormal Recycle: fault stack sensor
353
Abnormal Recycle: stack limit
354
Abnormal Recycle: delta T limit
355
Abnormal Recycle: fault outlet sensor
356
Abnormal Recycle: outlet high limit
357
Abnormal Recycle: fault DHW sensor
358
Abnormal Recycle: DHW high limit
359
Abnormal Recycle: fault inlet sensor
360
Abnormal Recycle: Check Parameters Failed
Internal Errors
361
Internal error: No factory parameters were
362
Internal error: PID iteration frequency was invalid
363
Internal error: Demand-Rate interval time was
364
Internal error: Factory calibration parameter for
365
Internal error: CH PID P-scaler was invalid
366
Internal error: CH PID I-scaler was invalid
367
Internal error: CH PID D-scaler was invalid
368
Internal error: DHW PID P-scaler was invalid
369
Internal error: DHW PID I-scaler was invalid
370
Internal error: DHW PID D-scaler was invalid
371
Internal error: Lead Lag master PID P-scaler was
372
Internal error: Lead Lag master PID I-scaler was
373
Internal error: Lead Lag master PID D-scaler was
374
Abnormal Recycle: Hardware flame bias high
375
Abnormal Recycle: Hardware flame bias low
376
Abnormal Recycle: Hardware flame bias delta
377
Abnormal Recycle: Hardware flame bias delta
378
Abnormal Recycle: Hardware flame bias
379
Abnormal Recycle: Hardware flame bias
380
Abnormal Recycle: Fan Speed Not Proven
117
CB FALCON
Description
750-265

Advertisement

Table of Contents
loading

Table of Contents