19
. ELECTRIC STARTER
XCITING 500
Starter Relay Switch
CONTINUTY INSPECTION
Disconnect the starter relay switch connector
and cables.
Connect a fully charged 12 V battery positive
wire to the relay switch Yellow/Red wire
terminal and negative wire to the Green wire
terminal.
There should be continuity between the cable
terminals while the battery is connected, and no
continuity when the battery is disconnected.
19-8