KYMCO XCITING 500 Service Manual page 324

Hide thumbs Also See for XCITING 500:
Table of Contents

Advertisement

19
. ELECTRIC STARTER
(From previous page)
Check for loose or poorly
connected starter relay switch
terminals.
Normal
Check for loose or poorly
connected or broken starter
motor cable.
Normal
With the ignition switch
turned to "ON", push the
starter switch and check for a
click sound from the starter
relay switch.
No clicks
Check the starter relay coil
ground line (page 19-7)
Normal
(Go to following page)
19-3
•Poorly connected terminal
Abnormal
•Poorly connected starter motor cable.
Abnormal
•Open circuit in starter motor cable.
Clicks
Connect the starter motor terminal
directly to the battery positive
terminal (Because a large amount of
current flows, do not use a thin wire).
Starter motor turns
•Loose or disconnected starter motor cable.
•Faulty starter relay switch.
•Faulty side stand switch.
Abnormal
•Loose or poor contact of connector.
•Open or short circuit in wire harness.
XCITING 500
Starter motor
does not turn
•Faulty starter motor.