18
. IGNITION SYSTEM
IGNITION PULSE GENERATOR
INSPECTION
Remove the luggage box (page 2-3).
Disconnect the ignition pulse generator
connector.
Measure the ignition pulse generator resistance
between the Green/White wire and Blue/Yellow
wire.
Standard: 516Ω (20ºC/68ºF)
IGNITION COIL
REMOVAL/INSTALLATION
Remove the floorboard (page 2-6).
Disconnect the spark plug cap from the spark
plug (page 18-4).
Disconnect the ignition coil primary connectors.
Remove the two nuts and the ignition coil.
Installation is in the reverse order of removal.
IGNITION CONTROL MODULE
REMOVAL/INSTALLATION
Remove the side body cover (page 2-8).
Disconnect the ignition control module
connectors and remove the ignition control
module.
18-5
Ignition Pulse Generator Connector
Ignition Control Module Connectors
Ignition Control Module