A/C Mode Door Control Cable (Yellow Cable)
1. Disconnect the air conditioner mode door control cable (3) from
the def. control lever (1) of A/C control panel side.
(When reassembling)
• Set the air conditioner unit to DEF mode position and reconnect
the cable (3).
• Set the control at DEF position. Fit the inner cable in position,
and press and fix the outer cable by the cable clip (2) in the
direction of arrow (B) as shown at left.
• Move the mode lever several times and finally set it to DEF
position to make sure the air conditioner unit is at DEF mode
position.
• Lay and fix the mode door control cable over the water valve
cable.
(1) DEF. Control Lever
(2) Cable Clip
(3) Mode Door Control Cable
Water Valve Control Cable (White Cable)
1. When disconnecting the water valve cable (2), follow the next
reassembly procedure.
(When reassembling)
• Fully close the water valve (1) and reconnect the cable (2).
• Set the control at MAX COOL position. Fit the inner cable in
position, and press and fix the outer cable by the cable clip (3) in
the direction of arrow (B) as shown at left.
• Move the temperature control lever several times to make sure
the water valve is fully closed at MAX COOL position.
• Do not allow the water valve cable to bend just away from the
control, not to get caught by the outer roof.
(1) Water Valve
(2) Water Valve Control Cable
(3) Cable Clip
10-S40
B : Direction of Pushing Outer Cable
W1030982
B : Direction of Pushing Outer Cable
W1031274